With absorption light, absorption light full wavelength scanning, fluorescence above and below detection, fluorescence full wavelength scanning, time difference fluorescence detection, cold light and two-color cold light detection mode
A set of light source system supports all detection modes, using Xenon flash lamp high energy xenon lamp, the lamp life is long, no need to warm up before use
The number of flashes of the xenon bulb can be adjusted according to different detection modes
When interpreting, the reference fiber will be passed through to detect the light source, and the correctness of the penetrating light source and the stability of the bulb flicker will be confirmed
Multi-calibration and interpretation can be performed, and absorbance and fluorescence detection and interpretation can be performed simultaneously in the same microplate
The full-wavelength optical system is the Quad4 Monochromator system, which can effectively filter stray light to 10-6 times. Using the rotating Monochromator Mirror, the scanning speed is fast and accurate.
Oscillation mode: Linear or Orbital Shaking, provides 6 amplitude frequencies, which can be finely adjusted by 0.5 mm
It can be directly operated on the panel, and the micro-disc in and out actions can be performed without going through a computer
Measuring speed:General 96-well plate, less than 20 seconds
Built-in power supply
Use voltage:120 - 240 Volt Auto Sensing
Host with USB 2.0 interface
Temperature Control:Room temperature +5 to 42°C
Service Item:
Use the characteristic of specific bonding between antigen and antibody to detect the sample; because the antigen or antibody bound to the solid carrier (usually a plastic well plate) can still have immunological activity, so after designing its bonding mechanism, With the color reaction of enzymes, the presence or absence of specific antigens or antibodies can be displayed, and quantitative analysis can be performed using the depth of coloration
Precautions for Sampling and Use:
Please prepare your own orifice plate
When closing the instrument, please close the software first, and then close the instrument
The price does not include sample preparation (such as tissue extraction), kits and reagents (must be provided by the customer or purchased on behalf of the customer)
The price is calculated by plate, if the sample quantity is less than one plate, it will be calculated as one plate
Hours of use and reservations:Required 7 days in advance
Training: Only for OEM, this system does not provide self-operation